Xtend Fixed Glass and Fixed Glass Profile

Download the drawing

Download PDF ↓

Frame cross-section for the factory-assembled Xtend fixed glass unit. Shows the powder-coated aluminum frame, stops, and tempered-glass placement, with the dimensions needed to plan the opening and visible glass area.

What this document covers

This drawing shows the frame cross-section for a fixed (non-operating) Xtend glass unit. The glass is factory-installed and sealed, so the document is primarily for planning the rough opening and understanding the visible glass area.

  • Frame cross-section with stop detail
  • Tempered glass placement
  • Frame opening to window-size relationship
  • Visible glass calculation
  • Sealant placement

Key specifications at a glance

  • Window width/height: frame opening less 1/4"
  • Visible glass: 3-3/4" less than the frame opening (width and height)
  • Glass: tempered, factory-installed and sealed
  • Stops: 3/4" x 3/4" with flat-head screws, factory installed
  • Frame: powder-coated aluminum, factory assembled
  • Scale: 1:2

Installation notes

Sealant: apply between the flange and framing on the top and both sides only. Fasteners: color-matched flat-head screws are provided; for aluminum framing, self-tapping hex-head screws can be provided.